2021ALCD Pin Type Moisture Meter

Descriptions:

This is a equipment to measure material moisture, environment temperature and humidity. Generally the user will use this device to measure the water containment of wood, building material, etc. Environment temperature and humidity can be the reference when user measures the water containment of the material.

Features:

  • LCD Display.
  • Auto shut off.
  • 5 category measurement for different material.
  • Environment temperature, environment humidity, material moisture measurement.

Specifications:

UNIT
ENVIRONMENT TEMPERATURE                            °C / °F
ENVIRONMENT HUMIDITY RH %
MATERIAL MOISTURE %
MEASUREMENT RANGE
CATEGORY 0 Environment Temperature 0-50°C                        
CATEGORY 1 Environment Temperature 32-122°F
CATEGORY 2 Environment Humidity 25-90% RH
CATEGORY 3 9-22% (wood with unknown density)
CATEGORY 4 10-60% (wood density about 0.65-0.8g/m3)
RESOLUTION
ENVIRONMENT TEMPERATURE 0.1 °C/°F
ENVIRONMENT HUMIDITY 0.1%
MATERIAL MOISTURE 0.1%
ACCURACY
ENVIRONMENT TEMPERATURE ±2°C@0-50°C
ENVIRONMENT HUMIDITY ±8%@10-80°%
MATERIAL MOISTURE ±1%@20-30°C
±2%@other temperature
MEASUREMENT SPEED
ENVIRONMENT TEMPERATURE REFRESH TIME < 0.5s
ENVIRONMENT HUMIDITY REFRESH TIME < 0.5s
MATERIAL MOISTURE REFRESH TIME < 0.5s
STORAGE AND OPERATING CONDITION
WORKING ENVIRONMENT 0-50°C @ <80% RH 
(without freeze)
STORAGE ENVIRONMENT -10-60°C @ <70% RH
(without freeze)
POWER
BATTERY 4 x 1.5V AAA
 INSTRUCTIONS
a) Power ON /OFF
  • Press ON/OFF button to switch on the power.
  • Press ON/OFF button again will switch off the power.
  • Device will auto power off after 10 minutes.
b) Material Category Selection
Press UNIT button to select the category after the device been powered on,  The category is listed following:
0: Environment Temperature (°C)
1: Environment Temperature (°F)
2: Environment Humidity
3: Wood with unknown density
4: Wood with density about 0.65-0.8 g/m3
c) Caution
  • For better accuracy, please repeat the measurement on multiple location with a material.
  • During category 3-4 measurement, please pull the probe into the material as deep as possible.
  • keep the interfere temperature / moisture source (eg. Hands) away from the testing probe.